Lay out a stair before you cut a stringer
Give it the rise from one finished floor to the next. It works out the risers, the treads, the run, the stringer and the angle, and holds the result up against the usual code limits.
Finished floor at the bottom to finished floor at the top. Not subfloor to subfloor.
Nose of one tread to the nose of the next. Ten is the minimum.
Optional. The floor the stair may take up, start to finish.
Inside the usual limits Riser and tread are both inside the usual residential limits.
The stair, by the numbers
| Risers | 14, each 7 11/16 in (7.714) |
|---|---|
| Treads | 13, each 10 in nose to nose |
| Total run | 10 ft 10 in (130 in) |
| Stringer length | About 14 ft 8 3/4 in. Cut it from a 16 foot 2x12. |
| Stair angle | 37.6 degrees up from level |
I start with the fewest risers the code allows. More risers make lower steps and a longer stair.
- Riser fine Each riser is 7 11/16 inches, inside the 7 3/4 inch limit.
- Tread fine A 10 inch tread meets the 10 inch minimum.
Every riser the same. The code allows 3/8 inch between the tallest riser and the shortest in a flight, and feet notice less than that. Round this riser to 7 11/16 and step it off 14 times and the top lands 3/8 inch off, all of it in one riser, which is at or past the limit by itself. Lay the stringer out from a running total, not one step at a time. The usual culprits are the top and bottom steps, after somebody adds tile, hardwood or a thicker tread. Measure from finished floor to finished floor, and take the tread thickness off the bottom of the stringer.
Check the headroom The code wants 6 feet 8 inches clear, measured straight up from the line of the tread noses to whatever is overhead. With about 12 inches of floor framing above, the hole in the upper floor has to be about 9 ft 11 1/4 in long to clear it on this stair. Measure your own floor and beams. This is where a stair that works on paper meets a header.
Where the limits come from: the International Residential Code, section R311.7. Risers no taller than 7 3/4 inches, treads no shallower than 10, no more than 3/8 inch of difference in a flight, 6 feet 8 inches of headroom. Apart from its energy standards, Vermont has no statewide building code for a single-family house the owner lives in, and towns differ a good deal on what they enforce. Some inspect and some don't. A rental or a public building answers to the state Division of Fire Safety. So the town, or the state fire safety office, has the last word on your stair. What I assumed: a straight flight, the upper floor as the top step, and a stringer figured a little long. It doesn't figure width, handrails, guards, landings or winders, and it doesn't size the stringers. A computer did this arithmetic and it's a rough guide.
What the numbers are based on
A stair is division. Take the height from finished floor to finished floor, divide it by a riser no taller than the code allows, and round up to a whole number of steps. Divide the height again by that number and you have the riser every step has to share. Treads are one fewer than risers, since the upper floor does the job of the last one. The run is the treads laid end to end, and the stringer is the long side of that triangle.
The limits it checks against are from the International Residential Code: a riser of 7 3/4 inches at most, a tread of 10 inches at least, no more than 3/8 inch between the tallest riser and the shortest, and 6 feet 8 inches of headroom.
What it can’t tell you
Whether your town holds a single-family house to those figures. Apart from its energy standards, Vermont has no statewide building code for a house the owner lives in. Some towns and cities inspect and many don’t, and rentals and public buildings fall under the state Division of Fire Safety. Ask before you build. I’d build to the numbers regardless. Nobody notices a good stair, and everybody notices a bad one, usually with a laundry basket in their arms.
It also can’t see your house. It doesn’t know about the beam overhead, the door at the bottom, or the tile somebody will lay on the upper floor next year. It leaves out winders, landings, handrails and guards, and it doesn’t size a stringer. A long stair, an open one, or one hung off a deck over a bank should be looked at by somebody who will stand behind it.
If the stair won't fit
Send me the numbers and a photo of where it has to go. A stair that fights the house usually means the layout around it needs another look, and that is easier on paper than in lumber.
(802) 992-8119Call or text. If I don’t pick up, leave a message and I’ll call you back.