Start with the house and the heating plant gets easier. A tight, well insulated house needs a small system, and a small system is simpler to get right. Most of the heating regret I hear about comes from doing it the other way around: an ordinary shell with a big machine bolted on to make up for it.
Size it to the house
Vermont's 2024 energy standard requires a heating load calculation for a new house and requires the equipment to be sized to it, with limits on oversizing. (Since July 2026 a builder may follow either the 2020 or the 2024 edition, so ask which one applies to yours. The sizing advice holds either way.) The handbook gives eleven below zero as the default outdoor design temperature for Vermont.
Oversized equipment is the common mistake. It satisfies the thermostat fast, shuts off, starts again, and never settles into the long steady run where it works best. The calculation belongs to the heating contractor or designer. Ask to see it.
Heat pumps
A heat pump moves heat from one place to another instead of making it by burning something. In the heating season it pulls heat out of the outside air, cold as that air is, and brings it indoors.
Under the 2024 standard, a heat pump has to be a certified cold-climate model, or a variable-capacity type that still meets a set efficiency at 5 degrees. Units built for milder places don't qualify. The same standard generally prohibits electric resistance heat, with a short list of exceptions.
Things I'd think about:
- Ductless heads heat the room they're in. That suits an open plan. Closed bedrooms down a hall need heads of their own, a small ducted unit, or some other answer.
- If the system is ducted, the 2024 standard wants every duct and the air handler inside the heated part of the house. Nothing in the attic.
- The outdoor unit sits up above the snow, out from under the roof edge where snow and ice come off, with room around it to breathe and to drain when it defrosts.
- Many of them cool in summer as well, which is new for a lot of Vermont houses.
Boilers and furnaces
Plenty of new houses still get a boiler or a furnace, burning gas where there's a main in the road, and propane, oil or wood pellets where there isn't. A boiler can feed radiators or tubing in a slab. In a tight house, a burner ought to take its combustion air from outdoors and send its exhaust straight out.
There's nothing backward about a good boiler in a good shell. Think about where the fuel is stored, how the delivery truck reaches it in February, and what that fuel may cost in fifteen years, which nobody knows.
Wood
A wood stove earns its place in a Vermont house the first time the power is out for two days. The 2024 standard requires solid fuel appliances to have tight-fitting gasketed doors and combustion air supplied directly from outdoors. In a tight house that matters, because a stove starved for air will try to pull it back down the chimney.
The handbook also notes that wood is never counted as the primary fuel when the house has another automatic heating system. Plan the stove as the second system and it'll do that job well. A chimney that runs up through the inside of the house draws better than one hung on an outside wall.
Fresh air
A tight house has to be ventilated on purpose. The 2024 standard requires a whole-house balanced ventilation system in every new home except tiny houses. Balanced means a machine that brings in as much outside air as it sends out, usually passing the two streams by each other so the outgoing air warms the incoming. It runs quietly all the time, and it's the reason a tight house smells better than a leaky one.
Bathrooms still get exhaust fans, and the standard requires makeup air for an exhaust system of 400 cubic feet per minute or more, which is big-range-hood territory.
Hot water
Decide this along with the heat. A boiler can make the hot water. A house heated by heat pumps needs a separate water heater, and a heat pump water heater is one choice, though it wants a spot with some air around it and somewhere to drain.
Power
Heating with electricity means the electrical service has to be up to it. The 2024 standard calls for at least 200 amp service in a new house. If outages worry you, and on some roads they should, talk through what will run without the grid: a wood stove, a generator connection, or both.
Alarms
The state Division of Fire Safety says carbon monoxide alarms are required near the bedrooms in all new dwellings, along with photoelectric smoke alarms near the bedrooms and on each level. In a new house they're wired to the building's electrical service and carry a battery backup.
Who decides what
Heating is its own trade, and a new house needs somebody from that trade involved while the house is still on paper. My part is building a shell that doesn't waste what the system makes, and leaving that system a place inside the shell to live. Pipes, ducts and equipment need room, and room is easy to find before framing and hard to find after.
Efficiency Vermont and the utilities run incentive programs for some of this equipment. The programs change, so check what's current before you choose, and don't pick a heating system for the rebate.
Is this your project?