A hot shower puts a surprising amount of water into the air of a small room. In July it drifts out the window and nobody thinks about it. In January that warm, wet air goes looking for the coldest surface it can reach, and in a Vermont house there are plenty to choose from.
Most of the rot and mold I've seen in bathrooms came down to that. The tile was fine. The air was the problem.
Where the water ends up
Warm air rises and leaks. It goes up through the hole around the fan housing, the light fixtures, the top of the plumbing wall. Up in the attic it meets roof boards that are well below freezing, and the water comes out of it as frost. On the first warm day the frost melts and drips onto the insulation and the ceiling. It looks like a roof leak that only happens in a thaw. Often the roof has nothing to do with it.
The same thing happens inside an outside wall, slower and out of sight. And it happens on the room side, on the window, the cold corner behind the toilet, the ceiling over the shower. That's where the gray spots start.
The Health Department puts it simply: mold needs moisture, and if you don't fix the moisture the mold comes back. Everything below is about the moisture.
The fan does most of the work
Vermont's energy code handbook is specific on this. Any bathroom with a tub or shower has to have an exhaust fan, with a tested capacity of at least 50 cubic feet a minute if it runs when switched on, or 20 if it runs all day and night. Treat that as the least you can get by with. A bigger bathroom or a long duct needs more fan.
The fan is only as good as its duct. What I want to see:
- The duct runs to the outdoors, through the roof or a wall, with a proper hood. Never into the attic, and never just aimed at a soffit vent.
- The run is short and as straight as the framing allows. The handbook calls for smooth-wall duct on any run over 8 feet.
- Joints are fastened and sealed with something better than cloth duct tape, which the handbook rules out because it dries up and lets go.
- The fan housing is sealed to the ceiling so room air can't slip around it into the attic.
- There's a damper that shuts when the fan is off, so the cold doesn't blow back in.
- The duct stays inside the insulated part of the house as far as it can. Where it has to cross a cold attic, it gets buried in insulation, or it will sweat and drip back down.
Then somebody has to run it. A fan that goes off with the light when you leave does half a job, because the room is still wet. Put it on a timer or a humidity control and let it run on after the shower. A quiet fan helps more than you'd think. People turn off a loud one.
The state now lets a job follow either the 2020 or the 2024 edition of the energy standards. The Energy Code Assistance Center at 855-887-0673 can tell you what applies to yours.
Behind the tile
Tile and grout are a wearing surface. They don't keep water out, and neither does the cement board behind them. Something in that wall has to be the waterproof layer, whether it's a sheet membrane or one that's rolled on, and it has to be continuous from the pan or tub flange up past the showerhead. Corners, niches and the valve opening are where it gets skipped and where it leaks.
A shower on an outside wall takes more thought. That wall needs insulation and a tight air seal behind the waterproofing, and it needs to be able to dry in one direction or the other. Two layers that both stop vapor, with wet wood between them, is how a wall rots without ever showing a stain.
If there's a choice, keep supply pipes out of outside walls entirely. A pipe in an outside wall in this climate is a freeze-up waiting for the right night.
The floor
On the floor, the weak points are the edge of the tub and the base of the toilet. Water that gets under the flooring there sits on the subfloor for years. Seal the tub edge and keep it sealed. On a remodel I look at the subfloor at both spots before any new floor goes down.
Old houses
Bathrooms in old houses were mostly added long after the house was built, and they were fitted in wherever they'd go. It's common to find floor joists cut for the drain and an outside wall with no insulation in it at all.
Opening those walls is the time to fix both. The handbook says a cavity exposed during the work is to be filled with insulation, and I'd fill it regardless.
How to tell it's working
You don't need instruments, though a cheap humidity gauge is handy. The Health Department's guidance is to keep indoor humidity between 40 and 60 percent.
- The mirror clears within a few minutes of the shower ending.
- No dark spotting on the ceiling or in the corners.
- No frost on the roof boards over the bathroom in a cold snap. Go look once.
- Paint that stays on.
If the mirror is still fogged a half hour later, the fan isn't moving air, whatever it sounds like. Hold a square of toilet paper up to the grille. If the fan won't hold it there, start with the duct.